DSOD703-BL Oil Spill Detector for Light Oils

Model: DSOD703-BL
Monitorable oils: Gasoline, Kerosene, Diesel, Jet Fuel, and other light oils;
Certification: CE, Ex db IIC T6 Gb (CNEX)
Measurement range: 0- 1.2 m from surface
Size: φ101*113mm
Principle: UV fluorescence method
Interface: RS485/ 4-20mA/ Relay Output

1. Overview of the DSOD703-BL Oil Spill Detector

The Desun Uniwill DSOD703-BL Oil Spill Detector for Light Oils is a non-contact optical sensor that detects compatible light petroleum products on water surfaces. Using UV fluorescence technology, it helps identify potential oil contamination and triggers alarms for timely inspection and spill response.

DSOD703-BL Oil Spill Detector for for Light Oils - Desun Uniwill

The DSOD703-BL is intended for monitoring light petroleum products such as gasoline, kerosene, jet fuel, and diesel, subject to the target oil’s optical characteristics and the installation conditions. It is suitable for applications where fuel leakage or oil film contamination may threaten water quality, industrial operations, or environmental safety.

Typical applications include airports, aviation fuel storage facilities, fuel depots, oil terminals, tank farms, petrochemical plants, fuel loading and unloading areas, pipelines, pumping stations, water intakes, and drainage outlets.

For facilities handling light fuels, early detection can help operators identify potential contamination, activate alarms, and initiate appropriate response procedures before a spill spreads further.

Why Choose a Dedicated Oil Spill Detector for Light Oils?

Different petroleum products can have different fluorescence characteristics. A detector’s suitability therefore depends on the target oil, expected oil film conditions, installation distance, and environmental interference.

The DSOD703-BL has been developed specifically for light-oil detection applications. Compared with the DSOD703-A and DSOD703-B, which are primarily intended for heavier petroleum products such as heavy crude oil, heavy fuel oil, marine fuel oil (MFO), lubricating oil, hydraulic oil, and transformer oil, the DSOD703-BL is positioned for monitoring lighter petroleum products and fuels.

Choosing a detector according to the target oil type helps engineers select a configuration appropriate for the intended monitoring application.

Note: Actual detection performance depends on the oil type, oil film characteristics, installation conditions, and configured detection parameters. Target-oil compatibility should be confirmed before deployment.

2. Working Principle: UV Fluorescence Oil Spill Detection

The DSOD703-BL uses ultraviolet (UV) fluorescence technology to detect compatible oil films without direct contact with the water.

Working Principle of DSOD703-BL Oil Spill Detector - Desun Uniwill

The detection process works as follows:

  • UV excitation: The sensor directs ultraviolet light toward the monitored surface.
  • Fluorescence detection: When compatible petroleum hydrocarbons are present, they produce a characteristic optical response under suitable excitation conditions.
  • Signal analysis: The detector processes the received optical signal according to its detection settings.
  • Alarm output: When the configured detection conditions are met, the detector generates an alarm signal that can be transmitted to an external monitoring or control system.

Oil Spill Detector Alarm System Schematic - Desun Uniwill

This non-contact detection method avoids direct immersion of the sensing element in the monitored water, helping reduce contact-related contamination and maintenance requirements.

For continuous monitoring applications, the detector can serve as a field detection point within a broader oil spill alarm and monitoring system.

3. Technical Specifications of the DSOD703-BL

The following table provides a framework for presenting the DSOD703-BL’s technical specifications to engineers and project procurement teams. Confirm the values against the official product datasheet before publication.

Product NameOil Spill Detector for Light Oils
ModelDSOD703-BL
Monitorable oilsGasoline, Kerosene, Diesel, Jet Fuel, and other light oils;

Heavy Crude Oil, Heavy Fuel Oil, Marine Fuel Oil (MFO), Lubricating oil, Hydraulic oil, Transformer oil and other petroleum-based products.
CertifactionCE, Ex db IIC T6 Gb (CNEX)
Measurement range0-1.2m from surface
Power wastage< 2 W(DC)
Sizeφ101*113mm
PrincipleUV fluorescence method
Sensitivity≥ 1μm (micron) oil film
Response Time<5s
False Alarm Rate<1%
InterfaceRS485/ 4-20mA/ Relay Output
Power supply12-24 VDC (10V-30V) as standard
Protection LevelIP66
Operating Temperature-30-60℃
Housing materialStainless Steel/ Titanium alloy
Warranty2-years factory warranty as standard, supported worldwide
Light Source Lifetime5 years, replaceable light source

For engineering projects, confirm the required detection distance, mounting height, output signals, power supply, environmental conditions, and hazardous-area requirements before selecting a configuration.

4. Key Features and Benefits

4.1 Designed for Light Petroleum Products

The DSOD703-BL is developed for light-oil monitoring applications involving compatible fuels such as gasoline, kerosene, jet fuel, and diesel.

Its dedicated product positioning helps customers identify a suitable detection solution for fuel-handling facilities, water monitoring points, and other locations where light-oil contamination may occur.

4.2 Non-Contact Optical Detection

The detector monitors the target surface without direct contact with the water. This design helps reduce sensor fouling associated with immersion-based measurement and supports monitoring at suitable water surfaces, drainage points, and collection areas.

Reduced contact-related contamination can help simplify routine maintenance, although the optical window and installation environment may still require inspection and cleaning.

4.3 Flexible Industrial System Integration

Depending on the selected configuration, the DSOD703-BL supports RS485, 4–20 mA, and relay outputs for integration with industrial monitoring and control systems.

It can be used as an individual detection point or incorporated into a larger oil spill detection and monitoring system connected to:

– PLC-based alarm and control systems

– SCADA monitoring platforms

– DCS process control systems

– Local audible and visual alarm devices

– Centralized environmental monitoring systems

This integration enables operators to receive detection signals at a designated control point and implement site-specific response procedures.

4.4 Configurable Alarm Response

The alarm response settings can be adjusted according to site requirements and supported product configurations.

Appropriate configuration allows project engineers to align alarm behavior with the monitoring objective, the expected spill conditions, and the site’s response procedures.

The final response time and alarm settings should be confirmed against the technical specifications and application requirements.

4.5 Intelligent Signal Filtering

Outdoor and industrial water surfaces may be affected by floating leaves, plastic debris, foam, waves, and other temporary disturbances.

The DSOD703-BL incorporates intelligent signal filtering designed to help reduce false alarms caused by such disturbances. Actual interference rejection depends on the specific surface conditions, installation environment, and detector settings.

Correct installation and application-specific commissioning remain important for reliable field operation.

5. Typical Applications of the DSOD703-BL

5.1 Airports and Aviation Fuel Facilities

Aviation fuel storage and handling facilities may require monitoring at selected drainage points and water surfaces where fuel leakage could lead to contamination.

The DSOD703-BL can be evaluated for detecting compatible light-fuel films at suitable monitoring locations around aviation fuel infrastructure.

5.2 Fuel Depots and Tank Farms

Fuel storage areas may include tanks, transfer lines, pumping equipment, and drainage infrastructure. Monitoring selected water collection points can provide an additional layer of early warning if compatible fuel reaches the monitored surface.

The detector can be incorporated into a facility’s broader leak detection and environmental monitoring arrangements.

5.3 Oil Terminals and Fuel Loading Areas

Fuel transfer operations may involve pipelines, loading equipment, storage tanks, and associated drainage systems.

At suitable locations, a non-contact oil spill detector can provide an alarm when compatible oil contamination is detected on the monitored water surface, helping operators initiate inspection and response procedures.

5.4 Petrochemical Plants and Industrial Facilities

Industrial sites may handle multiple petroleum products with different physical and optical characteristics.

The DSOD703-BL is intended for light-oil applications. The target substance should be confirmed before deployment, particularly where multiple fuels, chemicals, or other fluorescent substances may be present.

5.5 Pipelines and Pumping Stations

Pipelines and pumping stations can be potential sources of fuel leakage. Where a leak could reach a monitored drainage channel, collection pit, or water surface, a suitably installed detector can provide an additional warning point.

The detector’s suitability depends on whether the leaked product reaches the monitored surface and falls within the sensor’s validated detection conditions.

5.6 Water Intakes and Drainage Outlets

Water intakes and drainage outlets can be important monitoring locations where oil contamination may affect downstream water quality or nearby aquatic environments.

By detecting compatible oil films at selected monitoring points, the DSOD703-BL can support early warning and help operators coordinate appropriate inspection and containment measures.

6. DSOD703-BL vs. DSOD703-A and DSOD703-B

The DSOD703 series includes different models intended for different petroleum product detection and monitoring distance requirements. Selecting the appropriate model should begin with the target oil type and the actual site conditions.

Product NameOil Spill Detector/ Oil Film Detector/ Oil On Water Detector/ Oil Slick Detection Sensor
ModelDSOD703-A (0-10m)DSOD703-B (0-2m)DSOD703-BL (0-1.2m)
Detectable OilHeavy Crude Oil, Heavy Fuel Oil, Marine Fuel Oil (MFO), Lubricating oil, Hydraulic oil, Transformer oil and other petroleum-based products.Heavy Crude Oil, Heavy Fuel Oil, Marine Fuel Oil (MFO), Lubricating oil, Hydraulic oil, Transformer oil and other petroleum-based products.Gasoline, Kerosene, Diesel, Jet Fuel, and other light oils;

Heavy Crude Oil, Heavy Fuel Oil, Marine Fuel Oil (MFO), Lubricating oil, Hydraulic oil, Transformer oil and other petroleum-based products.
CertificateCECE, Ex db IIC T6 Gb (CNEX)CE, Ex db IIC T6 Gb (CNEX)
Measuring Distance0-10m from surface0-2m from surface0-1.2m from surface
Power Consumption< 7W(DC)< 2 W(DC)< 2 W(DC)
Dimensions (L x Ø)Φ110mm*406mmφ101*113mmφ101*113mm
PrincipleUV fluorescence method
Sensitivity≥ 1μm (micron) oil film
Response Time<5s
False Alarm Rate<1%
InterfaceRS485/ 4-20mA/ Relay Output
Power Supply12-24 V DC (10V-30V) as standard
Protection LevelIP66
Operating Temperature-30-60℃
Housing MaterialStainless Steel/ Titanium alloy
Warranty2-years factory warranty as standard, supported worldwide

The table describes the intended application positioning of the models.

How should you choose?

-If the target is a compatible light petroleum product, evaluate the DSOD703-BL.

-If the target is a heavier petroleum product, evaluate the DSOD703-A or DSOD703-B according to the product datasheet.

– If the facility handles multiple types of oil, provide the exact oil names and monitoring conditions so that the appropriate model can be assessed.

7. How to Select an Oil Spill Detector for Your Project

Before selecting an oil spill detector, project engineers and procurement teams should consider the following factors.

7.1 Target oil type

Identify the specific petroleum product, such as gasoline, kerosene, jet fuel, diesel, heavy fuel oil, or lubricating oil. Product names alone may not be sufficient to establish detection compatibility.

7.2 Installation location

Determine whether the detector will be installed above an open water surface, a drainage channel, a collection pit, a water intake, or another suitable monitoring point.

7.3 Detection distance

Specify the required distance between the detector and the monitored surface. Confirm that the selected configuration supports the intended installation geometry.

7.4 Environmental conditions

Consider waves, foam, floating debris, changing water levels, ambient lighting, weather exposure, and other possible sources of interference.

7.5 Alarm and communication requirements

Determine whether the system needs relay alarms, 4–20 mA signals, RS485 communication, or integration with a PLC, SCADA, or DCS platform.

7.6 Hazardous-area requirements

For fuel storage, transfer, and processing facilities, identify whether the installation area is classified as hazardous. Verify the applicable certification and installation requirements before ordering.

Providing these details helps the manufacturer assess the suitability of the detector and recommend an appropriate configuration.

8. Frequently Asked Questions

What is an oil spill detector for light oils?

An oil spill detector for light oils is a device designed to identify compatible light petroleum products or oil films at a monitored location. The DSOD703-BL uses non-contact UV fluorescence technology for light-oil monitoring applications.

Which oils can the DSOD703-BL detect?

The intended applications include gasoline, kerosene, jet fuel, diesel, and other compatible light petroleum products. Actual detection performance depends on the target substance and operating conditions. Confirm compatibility with Desun Uniwill before deployment.

Does the DSOD703-BL need to contact the water?

No. The DSOD703-BL uses non-contact optical detection and does not need to be immersed in the monitored water. The detector must still be installed at an appropriate distance and angle for the selected configuration.

Can the DSOD703-BL be integrated with a SCADA or PLC system?

Depending on the selected configuration, the detector supports signal outputs such as RS485, 4–20 mA, and relay outputs. Confirm the available interfaces and communication requirements when specifying the system.

Can the detector be used in a fuel storage facility?

It can be evaluated for suitable monitoring points at fuel storage and handling facilities where compatible oil contamination may reach the monitored surface. Hazardous-area suitability, detection distance, and the applicable certification must be verified for the intended installation.

How do I choose between the DSOD703-BL and other DSOD703 models?

Start by identifying the target petroleum product. The DSOD703-BL is intended for light-oil detection, while the DSOD703-A and DSOD703-B are primarily positioned for heavier petroleum products. Provide the exact oil type and installation conditions to determine the appropriate model.

9. Installed Project

Desun Uniwill DSOD703-BL Oil Spill Detectors for Underground Diesel Storage Tank Leak Monitoring

Desun Uniwill DSOD703-BL Oil Spill Detectors for Underground Diesel Storage Tank Leak Monitoring

The DSOD703-BL oil spill detector is installed above the ground surface near the underground diesel storage tank.

If leaking diesel reaches the ground surface and enters the detector’s effective detection area, the detector can identify the oil and trigger an alarm. This helps the customer detect surface oil leaks promptly.

10. Recommended Installation Method

DSOD703-BL Oil Spill Detector Recommended Installation Method - Desun Uniwill

Non-contact installation: Fixed installation above the water or ground surface.

11. Oil Spill Detector Orders Have Been Shipped to Overseas Customers

DSOD703-B Oil Spill Detectors Orders - Desun Uniwill

12. Get a Solution for Your Light-Oil Monitoring Application

Early detection of fuel contamination is an important part of environmental protection and industrial risk management. At suitable monitoring points, a non-contact detector can provide an additional warning mechanism to help operators identify potential oil spills and initiate timely response procedures.

The Desun Uniwill DSOD703-BL Oil Spill Detector for Light Oils combines UV fluorescence detection, non-contact monitoring, configurable alarm functions, and industrial system integration options for light-oil detection applications.

Whether you are planning a monitoring system for an airport, fuel depot, oil terminal, tank farm, petrochemical plant, or drainage outlet, our team can help evaluate the detector’s suitability for your project.

Contact Desun Uniwill for technical information and model selection.

To help us assess your requirements, please provide:

– Target oil type

– Installation location

– Required detection distance

– Power supply and signal output requirements

– Hazardous-area classification, if applicable

Our team can then review the application requirements and help you identify a suitable DSOD703-BL configuration.

Tags: Oil Spill Detector for Light Oils, UV Fluorescence Oil Detection, DSOD703-BL oil spill detector, light oil spill detection, oil spill monitoring system, gasoline spill detector, kerosene spill detector, jet fuel spill detector, diesel spill detection, light petroleum product detection, suppliers, manufacturers, factory, company, China, wholesale, buy, price, quotation, bulk, for sale, companies, stock, cost.

Related Videos

Reviews

There are no reviews yet.

Be the first to review “DSOD703-BL Oil Spill Detector for Light Oils”

Your email address will not be published. Required fields are marked *

Update cookies preferences