Description:
DS380 series of fluorescent dissolved oxygen sensor use a new generation of fluorescence lifetime technology and high performance fluorescent materials. No oxygen consumption,No flow rate limitation, no electrolyte, no maintenance and calibration,no interference from hydrogen sulfide, excellent stability. Built-in temperature sensor, automatic temperature compensation. RS485 output, can be networked without a controller.
Features of Dissolved Oxygen Sensor:
- DO Sensor, RS485 output, support MODBUS, which can realize networking and system intergration without a controller.
- There is no electrolyte, no interference, no need for frequent calibration.
- No oxygen consumption, no flow rate limit.
- Built-in temperature sensor, automatic temperature compensation.
- Water filter membrane, will not be attached to pollutants in the water.
- Good stability, high measurement accuracy and fast responding.
Technical parameter:
Item | Parameters |
---|---|
Model | DS380 |
Principle | Optical fluorescence method |
Measuring range | 0~20mg/L or 0-200% saturation |
Response time | 5 sec |
Accuracy | 5% |
Sensor drift | <1% per year |
Protection level | IP68 |
Installation | Drop in |
Temperature sensor | NTC |
Temperature range | 0~50°C |
Temperature accuracy | ±0.2°C |
Output | Support RS-485, MODBUS protocol |
Power supply | DC 6~12V, current <50mA |
Size | Φ26*177.5 mm |
Probe cable length | Default 10 m, customizable 5 m, 15 m and 30 m cable |
Fluorescent cap life | 1 year |
Maximum working pressure | 6bar |
Housing material | POM / Stainless steel, titanium alloy |
Applications:
Dissolved oxygen sensor is a sensing device used to measure the dissolved amount of oxygen in water. Dissolved oxygen sensors are widely used in aquaculture such as fish ponds, sewage treatment industry, hydrological monitoring, environmental monitoring, and in education and scientific research.
For aquaculture, if the DO level falls too low then the fish will suffocate as a consequence.
In a sewage treatment plant, bacteria will decompose the solids. If the DO level is too low, then the bacteria will die and the decomposition will cease; if the DO level is too high, then the energy will be wasted through the aeration of the water.
Customer Cases in Aquaculture:
China Water Quality Sensor Manufacturer:
Why Choose Desun Uniwill?
Video:
Related Products: Portable Handheld Dissolved Oxygen Meter
Related Articles:
WHICH WATER QUALITY SENSORS ARE COMMONLY USED IN AQUACULTURE?
THE IMPORTANCE OF DISSOLVED OXYGEN SENSORS FOR AQUACULTURE
DISSOLVED OXYGEN SENSOR AQUACULTURE
THE ROLE OF FLUORESCENCE DISSOLVED OXYGEN SENSOR IN AQUACULTURE
EFFECT OF DISSOLVED OXYGEN SENSOR IN PENAEUS VANNAMEI CULTURE
Reviews
There are no reviews yet.